quiz bu lëkkale ak tegtal · Dëgër Niveau
AI Teela Àrtu Njortu ngir Malaad Deterioration Quiz
Dafay saytu màndarga yi am solo yi NEWS2 di jëfandikoo, lu tax Kaiser Advance Alert Monitor am solo, ak lu tax AUROC kese mën na réer suñuy jàngat xeetu yàqu-yàqu yi.
Laaj 1 de 8
Ci yii, yan ci ñoom mooy benn ci parametre yiñ jox poñ ci NEWS2?
Xoolaatal laaj bu nekk8 laaj
Sooy def quiz bi, tontu yi ak leeral yi dañuy feeñ.
- Ci yii, yan ci ñoom mooy benn ci parametre yiñ jox poñ ci NEWS2?
- Serum creatinine
- Use of supplemental oxygen
- White blood cell count
- Blood lactate
- Lan moo nekkoon màndarga bi Kaiser Permanente dugal ci monitëru àrtu bu njëkk bi?
- Alerts went straight to patients' phones
- The model ran only in ICUs
- Trained remote nurses screened alerts before they reached the bedside team
- Alerts automatically ordered antibiotics
- Lan moo waral guide bi di wax ni AUROC bu yéeg du garanti pajum bu gëna baax?
- What matters is how often an alert is right at the chosen threshold, the number of alerts per shift, lead time and whether the response changes treatment
- AUROC only works for imaging models
- AUROC is always lower for AI than for NEWS2
- AUROC measures cost, not accuracy
- Lan moo waral komànd yi ngir lactate wala culture deret mëna waral xeetu yàqu-yàqu bi di ëpp njariñ li ci nekk?
- They slow down the EHR
- They are recorded in the wrong units
- They reset the model's score to zero
- They signal that clinicians already suspect trouble, so the model may flag deterioration staff have already recognized
- Lan moo waral xayma AUROC ci kaw seetlu bu nekk di yokk performance model buy yàqu?
- Stable patients contribute hundreds of easy negative observations
- It double-counts deaths
- It ignores vital signs
- It only includes ICU patients
- What is the purpose of running a deterioration model in silent mode before go-live?
- To hide the model from regulators
- To reduce electricity use
- To compute scores without showing them, so the hospital can measure local calibration, subgroup performance and alert volume
- To train nurses without any patient data
- If a deterioration model's positive predictive value at the alert threshold is 0.1, what is the number needed to evaluate?
- 1
- 10
- 0.1
- 100
- What did the University of Michigan's 2021 independent evaluation of Epic's sepsis model show?
- It performed exactly as the vendor reported
- It worked only for children
- It could replace blood cultures
- It performed substantially worse than the developer had reported