quiz bu lëkkale ak tegtal · Diggante Niveau

Maskeeru waxtu-fréquence ngir quiz tàqale ab balluwaay

Teg masku binär, ratio ak masku complex, xam seen diggante ak fase jaxase, te ràññee jàngat ak soppi caveats.

Laaj 1 de 8

naka lay def ba masku jot-frequence defar xayma biñ bëgga jëlee ci njaxasu STFT?

Xoolaatal laaj bu nekk8 laaj

Sooy def quiz bi, tontu yi ak leeral yi dañuy feeñ.

  1. naka lay def ba masku jot-frequence defar xayma biñ bëgga jëlee ci njaxasu STFT?
    • Use the clean target spectrogram as the output without consulting the mixture
    • Apply one constant gain to the entire recording
    • Multiplies the mixture representation by bin-wise weights
    • Assign a single source label to the whole clip
  2. Ban valeur mooy màndargaal masku binar bu baax ci liggéey bu yomb bu am ñaari balluwaay?
    • A continuously varying real weight across the unit interval
    • Zero or one
    • A complex-valued correction with arbitrary phase
    • The same gain for every time-frequency bin
  3. Lan moo mëna wuutale masku ratio ak masku binar bu dëgër?
    • It must assign every bin exactly zero or one
    • It guarantees that no interference remains
    • It ignores relative source strength when defining its weights
    • It can represent graded contributions with soft values
  4. Lan la mask bu jaffe mëna def lu masku magnitude dëgg mënul defar?
    • Phase as well as magnitude
    • Only magnitude, never phase
    • Only the mixture phase, with no magnitude change
    • Only a scalar gain applied to the whole waveform
  5. Ban fase lañuy faral di jëfandikoowaat su masku magnitude bu am valeur dëgg defaraat ab target buy jaxasoo?
    • The clean target's original phase supplied independently
    • A separately estimated target phase for every real-valued mask
    • The mixture phase
    • Zero phase imposed on every bin
  6. Why should a ratio-mask definition be stated explicitly?
    • All valid ratio masks are hard binary decisions
    • Different methods define ratios using magnitudes or powers
    • Ratio masks are computed from logarithms only
    • Every ratio mask uses exactly the same exponent and target definition
  7. What should match between masking and waveform reconstruction?
    • Any hop size works if the final duration is forced to match
    • The synthesis window is irrelevant after masking
    • The inverse transform can infer every analysis convention from mask values alone
    • Compatible STFT window and hop settings
  8. Which evaluation approach is useful for separated speech?
    • Combine appropriate signal metrics with listening or downstream tests
    • Treat a visually smooth mask as proof of clean separation
    • Report only the training objective on fitted mixtures
    • Assume waveform additivity guarantees perceptual quality