Guide-linked quiz · Medium Level

Statistical Process Control Charts Quiz

Tests Shewhart, CUSUM and EWMA signals, control versus specification limits, stable baselines, small shifts, investigation, and ML monitoring gaps.

Question 1 of 8

What does a point beyond a control-chart limit establish by itself?

Preview every question8 questions

Answers and explanations appear as you take the quiz.

  1. What does a point beyond a control-chart limit establish by itself?
    • The exact machine component that failed
    • Proof that the product violated every customer specification
    • A signal to investigate a departure from the modeled baseline, not its cause
    • A reason to recalculate limits immediately around the new point
  2. How do control limits differ from product specification limits?
    • They are always numerically equal when a process is stable
    • Control limits describe expected process variation under a baseline; specifications define acceptability
    • Control limits are legal quality standards set by the buyer
    • Specification limits are calculated only by an EWMA recursion
  3. Why can a small persistent mean shift escape a basic Shewhart chart for a while?
    • Shewhart charts remove all historic observations
    • A stable baseline prevents any change in the plotted process
    • The chart always uses a cumulative sum instead of individual points
    • Individual plotted statistics can remain inside limits despite repeated small departures
  4. What feature makes CUSUM useful for detecting sustained small changes?
    • It ignores every observation except the latest one
    • It accumulates departures from a target across successive observations
    • It automatically identifies the cause of drift
    • It guarantees no false alarms for a stable process
  5. In an EWMA chart, how are older measurements represented?
    • They receive diminishing weights through the recursive average
    • All older values receive the same weight as the newest value
    • They are deleted before each calculation
    • Only the oldest measurement is used as the baseline
  6. What should a team establish before interpreting an SPC signal?
    • A stable reference period, statistic, sampling plan and alert rule
    • Only the most recent outlying value
    • A new baseline recalculated after each alarm
    • A chart color scheme that labels all points acceptable
  7. A model's input-feature chart is stable, but outcome labels are not yet available. What remains unverified?
    • Whether the input pipeline returned any numbers
    • Whether a control chart has a center line
    • Whether the feature distribution stayed near the monitored baseline
    • Whether task performance on real outcomes changed
  8. After a documented, stable process redesign, how should old control limits be handled?
    • Move them automatically after every alarm
    • Treat them as permanent even when the process definition changed
    • Deliberately establish and document an appropriate new baseline
    • Discard all earlier monitoring records without an audit trail

Keep testing yourself

More quizzes picked for your level.

View all quizzes